Automotive Wire AVS copper structure

JASO AVS Copper Structure (PIW)


mm²
Copper
O.D.
KM / ROLL
0.3
7
/
0.260
1.40
±
0.05
0.700
0.5
7
/
0.320
2.00
±
0.10
0.700
0.75
10
/
0.320
2.20
±
0.10
0.700
0.85
11
/
0.320
2.20
±
0.10
0.700
1.25
16
/
0.320
2.50
±
0.10
0.700
1.5
19
/
0.320
2.70
±
0.10
0.700
2.0
26
/
0.320
3.10
±
0.15
0.600
2.5
32
/
0.320
3.30
±
0.15
0.600
3.0
41
/
0.320
3.80
±
0.15
0.600
5.0
65
/
0.320
4.60
±
0.20
0.400

For example : AVS 0.3mm²,  OD 0.26mm * 7pcs, pack in 700meters per roll

UL1015 Standard Copper Structure

UL1015 Standard Copper structure (PIW)

AWG
 Copper
O.D.
KM / ROLL
30
7
/
0.100
1.90
±
0.05
0.762
28
7
/
0.127
1.95
±
0.05
0.762
26
7
/
0.160
2.05
±
0.10
0.762
24
11
/
0.160
2.18
±
0.10
0.762
22
7
/
0.255
2.34
±
0.10
0.762
22
17
/
0.160
2.34
±
0.10
0.762
20
21
/
0.180
2.55
±
0.10
0.762
18
34
/
0.180
2.90
±
0.10
0.762
16
26
/
0.255
3.23
±
0.10
0.610
14
41
/
0.255
3.77
±
0.10
0.610
12
65
/
0.255
4.14
±
0.10
0.305
10
65
/
0.320
4.89
±
0.10
0.305



30AWG = OD 0.1mm copper X 7pcs

Friday, August 16, 2013

Halogen free cable

Halogen free cable are increasingly necessary especially in highly populated areas and industrial sites to protect against the risk of toxic gas emissions during fire. This type of cable has high performance, clean and it is a safer alternative to regular cables. Most standard RG cables contain halogen insulation. It is used because it helps to prevent the cables from fire.

 Halogen free cable does not contain Halogen-family elements such as Fluorine, Bromine, Iodine and Astatine. These element normally create toxic and corrosive fumes when burned. Therefore, it is suitable for public sector housing and major new development areas. Government in most country introduce stricter halogen regulations as the smoke created by burning the halogenated product is so dangerous to human health. Due to this, more and more manufacturers are making the effort to switch to halogen free options.
 Halogen free cable does function with the same standard and circular connectors with RG cables. It also offer a greater flexibility over standard RG cable. It is perfectly suitable in situation where performance, safety and reliability is highest in priority.Halogen-free cable also offers the added benefit of being more environmentally-friendly than their halogenated counterparts. Non-halogenated cables produce drastically lower levels of carbon monoxide – sometimes as much as 360% lower carbon output – and they produce less smoke overall.


For more wire and cable, please visit Pan-International 
contact : CT Loo

Thursday, August 15, 2013

UL3266 Specification



APPLIANCE WIRING MATERIAL
Subj.758     Section
 3 Page 3266   Issued:1972-05-30
                                  Revised:2011-08-16
Style
 3266 Single conductor with extruded insulation

Rating

125 deg C, 300 Vac, Horizontal flame.

Conductor

32 AWG - 10 AWG, solid or stranded.

Insulation

Extruded XLPE, 15 mils min average, 13 mils minimum at any point.

Standard

Appliance Wiring Material UL 758.

Marking

General.

Use

Internal Wiring. Tags may indicate the following: 600 Volts Peak - For Electronic Use Only.



UL1571 Specification


APPLIANCE WIRING MATERIAL
Subj.758          Section 1          Page 1571                                Issued:1972-12-27
Revised:2013-02-22
Style 1571                    Single cinductor with extruded insulation

Rating
80 deg C, 30 Vac, Horizontal flame.
Conductor
50 AWG minimum. Solid or stranded.
Insulation
Extruded PVC, SRPVC, foamed PVC, foamed SRPVC, XLPVC, XLSRPVC, foamed XLPVC or foamed XLSRPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness.
Covering
Optional. Extruded PVC, Nylon, ETFE, Polyester, XLPVC, XL Nylon, XLETFE or XL Polyester, 2 mils minimum thickness at any point, or lacquered braid.
Shield
Optional.
Jacket
Optional. Same as covering.
Shield
Optional.
Covering
Optional. Same as covering.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring of Class 2 Circuits in electronic equipment.



UL3385 Specification



APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3385 Issued:1980-01-29
                            Revised:2011-09-01

Style
 3385       Single conductor with extruded insulation
Rating
105 deg C, 300 Vac, Horizontal flame.
Conductor
32 AWG - 10 AWG, solid or stranded.
Insulation
Extruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
Shield
Optional.
Jacket
Optional, except when shield is used. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of appliances, tags may indicate the following: 600 Volts Peak - For Electronic Use Only.


UL1430 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section
 1 Page 1430   Issued:1967-04-06
                               Revised:2012-06-08

Style
 1430   Single Conductor with Extruded Insulation


Rating
105 deg C, 300 Vac, Horizontal Flame.
Conductor
30 AWG - 16 AWG, Solid or Stranded Round.
Insulation
Extruded XLPVC, 15 mils minimum average, 13 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring.