Tuesday, August 27, 2013

UL1618 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1618   Issued:1974-01-31
Revised:2013-03-04
Style 1618 single-conductor cable using non-integral covering

Rating
80 deg C, 300 Vac, Horizontal flame.
Insulated Conductor
Labeled or complying with the manufacturer's AWM Procedure.
Covering
Extruded PVC, 5 mils minimum thickness at any point, 50 mils maximum thickness.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.

UL2517 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2517   Issued:1970-10-21
Revised:2013-03-04

Style 2517 Multiple-conductor cable using non-integral jacket

Rating
105 deg C, 300 Vac, Cable Flame.
Insulated Conductor
Labeled or complying with Manufacturer's AWM Procedure. 40 AWG minimum.
Assembly
Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering
Optional.
Shield
Optional.
Jacket
Extruded PVC.



Diameter of Core Assembly under Jacket@
Minimum Average Thickness
Minimum Thickness at any point
0.700 inch or less
30 mils
24 mils
0.701 - 1.000 inch
45 mils
36 mils
1.001 - 1.500 inch
60 mils
48 mils
1.501 - 2.500 inch
80 mils
64 mils


Covering
Optional, braid.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: "600 Volts peak for Electronic Use Only".


Sunday, August 25, 2013

UL1617 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1617      Issued:1974-01-31
   Revised:2013-02-27
Style 1617 Single Conductor with Extruded Non-integral Covering
Rating
105 deg C, 600 Vac, Horizontal flame.
Insulated Conductor
Labeled or complying with the manufacturer's AWM Procedure.
Covering
Extruded PVC, 5 mils minimum thickness at any point, 40 mils maximum thickness.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring.


UL2468 Specification

APPLIANCE WIRING MATERIAL

Subj.758 Section 2 Page 2468  Issued:1968-05-07
Revised:2013-02-22
Style 2468       Flat ribbon cable

Rating
80 deg C, 300 Vac, Horizontal flame. Optional - 60 or 80 deg C Oil.
Conductor
32 AWG - 16 AWG, solid or stranded.
Insulation
Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
Assembly
Two to one hundred and fifty conductors laid parallel and in one plane. May use same or mixed AWG size. Minimum average and minimum at any point of insulation thickness after ripping shall be 15 mils and 13 mils, respectively. This forms a flat cable with a single row of conductors having a 1/2 in. maximum width web between insulated conductors.
Shield
Optional.
Covering
Optional, extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.

Thursday, August 22, 2013

UL1430 Standard Spec and km/roll

UL1430 (PIW)


AWG
SPEC.
O.D.
KM / ROLL
30
7
/
0.100
1.10
±
0.05
0.762
28
7
/
0.127
1.20
±
0.05
0.762
26
7
/
0.160
1.30
±
0.05
0.762
24
11
/
0.160
1.45
±
0.05
0.762
22
17
/
0.160
1.60
±
0.05
0.762
20
21
/
0.180
1.80
±
0.05
0.762
18
34
/
0.180
2.10
±
0.10
0.762
16
26
/
0.255
2.40
±
0.10
0.762

Unit : mm

Application :


For  internal wiring appliances, 600V peak - For electronic use only.


  • Rated Voltage 300 V (Spark voltage 3000 V)
  • Rated Temperature : UL, CUL 105 ºC
  • Conductor: bare or tinned annealed copper, stranded, solid or OS-1 copper conductor, 30 ~ 16AWG
  • Color-coded XLPVC insulation
  • Flame resistance VW-1 and CUL FT1 &JQA –F- vertical Flame test
  • Uniform thickness of wire to ensure easy stripping and cutting
  • Resistant to acids, oils, alkalis, moisture and fungus
  • RoHS Compliant
  • Hardness for insulation material : SHORE A 90 ± 5

Contact : CT Loo

Wednesday, August 21, 2013

Flexible wire

flexible wire 

The V-90HT single core hook-up 
flexible wire is suitable to be used for installation in plants, devices, switch gear cabinets and so on, where higher temperatures occur and at working voltages up to 600/1000V. V-90HT cable is using Tinned anneal copper wire strands and heat resistant PVC (V-90HT) insulation. The UL style is accordance in UL1015 which the flame retardant in accommodation to VW-1. 

Special Feature

-    Wide temperature range from -20◦C to 105◦C.
-    Rated voltage 600/1000V
-    Flame retardant to VW-1


More wire and cable please visit Pan-International

contact :  CT Loo 


Tuesday, August 20, 2013

UL20276 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section 2     Page 20276    Issued:1983-08-16
Revised:2013-02-25
Style 20276   Multiconductor cable with extruded non-integral jacket


Rating
60 or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on construction B.
Insulated Conductor
Labeled or complying with AWM Procedure. 40 AWG minimum.
Assembly
Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering
Optional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly.
Shield
Optional.
Jacket
Extruded PVC.


Construction A

Construction B


Diameter of core assembly under jacket
Minimum average thickness
Minimum thickness at any point
Minimum average thickness
Minimum thickness at any point

0.350 inch or less
20 mils
17 mils
15 mils
12 mils

0.351-0.700 inch
30 mils
24 mils
30 mils
24 mils

0.701-1.000 inch
40 mils
36 mils
40 mils
36 mils

1.101-1.500 inch
54 mils
48 mils
54 mils
48 mils


Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only.