Friday, September 6, 2013

UL1185 Specification

Subj.758 Section 1  Page 1185  Issued:1959-05-01
Revised:2011-10-24

Style 1185  Single conductor using extruded non-integral jacket.


Rating
80 deg C, 300 Vac, Horizontal flame.
Conductor
30 AWG - 4/0 AWG, solid or stranded.

Insulation

PVC

Conductor size
Minimum average thickness
Minimum thickness at any point

30-16 AWG
15 mils
13 mils

15-10 AWG
30 mils
27 mils

9-8 AWG
45 mils
40 mils

7-2 AWG
60 mils
54 mils

1-4/0 AWG
80 mils
72 mils

Assembly
Insulated conductor, optional shield, required jacket, optional shield, optional jacket.
Shield
Optional.

Jacket
Extruded PVC.

Conductor size
Minimum average thickness
Minimum thickness at any point


30-16 AWG
15 mils
12 mils


15-2 AWG
30 mils
24 mils


1-4/0 AWG
45 mils
36 mils


30-16 AWG
or lacquered braid



Outer Shield
Optional.
Outer Jacket
Optional. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring of Appliances and Electronic Equipment.


Contact : CT Loo 