Subj.758
Section 1 Page 1185 Issued:1959-05-01
Revised:2011-10-24
Style 1185 Single conductor using extruded non-integral
jacket.
Rating
|
80
deg C, 300 Vac, Horizontal flame.
|
Conductor
|
30
AWG - 4/0 AWG, solid or stranded.
|
Insulation
|
PVC
|
|||
|
Conductor size
|
Minimum average thickness
|
Minimum thickness at any
point
|
|
|
30-16 AWG
|
15 mils
|
13 mils
|
|
|
15-10 AWG
|
30 mils
|
27 mils
|
|
|
9-8 AWG
|
45 mils
|
40 mils
|
|
|
7-2 AWG
|
60 mils
|
54 mils
|
|
|
1-4/0 AWG
|
80 mils
|
72 mils
|
|
Assembly
|
Insulated
conductor, optional shield, required jacket, optional shield, optional
jacket.
|
Shield
|
Optional.
|
Jacket
|
Extruded
PVC.
|
|||
|
Conductor size
|
Minimum average thickness
|
Minimum thickness at any
point
|
|
|
30-16 AWG
|
15 mils
|
12 mils
|
|
|
15-2 AWG
|
30 mils
|
24 mils
|
|
|
1-4/0 AWG
|
45 mils
|
36 mils
|
|
|
30-16 AWG
|
or lacquered braid
|
|
Outer
Shield
|
Optional.
|
Outer
Jacket
|
Optional.
Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at
any point.
|
Standard
|
Appliance
Wiring Material UL 758.
|
Marking
|
General.
|
Use
|
Internal
Wiring of Appliances and Electronic Equipment.
|