UL1430 (PIW)
AWG
|
SPEC.
|
O.D.
|
KM / ROLL
|
||||
30
|
7
|
/
|
0.100
|
1.10
|
±
|
0.05
|
0.762
|
28
|
7
|
/
|
0.127
|
1.20
|
±
|
0.05
|
0.762
|
26
|
7
|
/
|
0.160
|
1.30
|
±
|
0.05
|
0.762
|
24
|
11
|
/
|
0.160
|
1.45
|
±
|
0.05
|
0.762
|
22
|
17
|
/
|
0.160
|
1.60
|
±
|
0.05
|
0.762
|
20
|
21
|
/
|
0.180
|
1.80
|
±
|
0.05
|
0.762
|
18
|
34
|
/
|
0.180
|
2.10
|
±
|
0.10
|
0.762
|
16
|
26
|
/
|
0.255
|
2.40
|
±
|
0.10
|
0.762
|
Unit : mm
Application :
For internal
wiring appliances, 600V peak - For electronic use only.
- Rated Voltage 300 V (Spark voltage 3000 V)
- Rated Temperature : UL, CUL 105 ºC
- Conductor: bare or tinned annealed copper, stranded, solid or OS-1 copper conductor, 30 ~ 16AWG
- Color-coded XLPVC insulation
- Flame resistance VW-1 and CUL FT1 &JQA –F- vertical Flame test
- Uniform thickness of wire to ensure easy stripping and cutting
- Resistant to acids, oils, alkalis, moisture and fungus
- RoHS Compliant
- Hardness for insulation material : SHORE A 90 ± 5
Contact : CT Loo
No comments:
Post a Comment