Cat5e cable (category 5 cable) is a twisted pair cable for computer networks. Since 2001, the variant commonly in use is the Category 5e specification (Cat 5e). The cable standard provides performance of up to 100 MHz and is suitable for most varieties of Ethernet over twisted pair up to 1000BASE-T (Gigabit Ethernet). Cat 5 is also used to carry other signals such as telephony and video.
This cable is commonly connected using punch-down blocks and modular connectors. Most Category 5 cables are unshielded, relying on the balanced line twisted pair design and differential signaling for noise rejection.
This cable is commonly connected using punch-down blocks and modular connectors. Most Category 5 cables are unshielded, relying on the balanced line twisted pair design and differential signaling for noise rejection.
For UL style, it will put under UL2835, the details of UL2835 is as follows:-
APPLIANCE WIRING MATERIAL
APPLIANCE WIRING MATERIAL
Subj.758
Section 2 Page 2835 Issued:1976-10-28
Revised:2013-02-25
Style 2835
Multiple-Conductor
Cable Using Extruded Non-Integral Jack et
Rating
|
60
deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use
No. 1A and 2A.
|
Conductor
|
40
AWG minimum.
|
Insulated Conductor
|
Material
not specified for Use No. 1A or 1B. Labeled or complies with manufacturer's
Procedure for Use No. 2A or 2B.
|
Assembly
|
Two
or more conductors, twisted pairs, or groups of twisted conductors. The
conductors may be laid parallel or twisted together to form a flat, oval, or
round cable construction. Lay not specified. Barrier layer and/or fillers
optional. May use same or mixed AWG sizes. Manufacturer shall maintain a
complete description of each assembly.
|
Covering
|
Optional.
Extruded PVC, 5 mils minimum thickness at any point, over the assembly or
groups of singles.
|
Shield
|
Optional.
May be over one or more of the insulated conductors or applied over the
assembly.
|
Extruded
PVC. If parallel construction is rippable, the measurements are made after
ripping.
|
Diameter of cable under
|
Minimum average thickness
|
Minimum thickness at any
point
|
|
0.250 inch or less (1A
|
2A only)
|
15 mils
|
13 mils
|
0.250 inch or less (1B
|
2B only)
|
30 mils
|
27 mils
|
0.251-0.424 inch
|
30 mils
|
27 mils
|
|
0.425-0.700 inch
|
60 mils
|
48 mils
|
|
0.701-1.500 inch
|
80 mils
|
64 mils
|
|
1.501-2.500 inch
|
110 mils
|
88 mils
|
|
2.501 inch or larger
|
140 mils
|
112 mils
|
* = Major diameter if flat or oval construction.
Standard
|
Appliance
Wiring Material UL 758.
|
Marking
|
General.
|
Use
|
Use
No. 1A:, Internal wiring in Class 2 circuits of electronic equipment where
each end is terminated in connectors.; Use No. 1B:, CABLES - using 30 mils or
greater ¤ ¤ ¤ Please contact : ctloo@pan-intl.com |