UL20276 Specification

APPLIANCE WIRING MATERIAL
Subj.758 Section 2     Page 20276    Issued:1983-08-16
Revised:2013-02-25
Style 20276   Multiconductor cable with extruded non-integral jacket


Rating
60 or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on construction B.
Insulated Conductor
Labeled or complying with AWM Procedure. 40 AWG minimum.
Assembly
Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering
Optional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly.
Shield
Optional.
Jacket
Extruded PVC.


Construction A

Construction B


Diameter of core assembly under jacket
Minimum average thickness
Minimum thickness at any point
Minimum average thickness
Minimum thickness at any point

0.350 inch or less
20 mils
17 mils
15 mils
12 mils

0.351-0.700 inch
30 mils
24 mils
30 mils
24 mils

0.701-1.000 inch
40 mils
36 mils
40 mils
36 mils

1.101-1.500 inch
54 mils
48 mils
54 mils
48 mils


Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only.