APPLIANCE
WIRING MATERIAL
Subj.758
Section 2 Page 20276 Issued:1983-08-16
Revised:2013-02-25
Style 20276
Multiconductor cable with extruded
non-integral jack et
Rating
|
60
or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on
construction B.
|
Insulated Conductor
|
Labeled
or complying with AWM Procedure. 40 AWG minimum.
|
Assembly
|
Consists
of two or more conductors, twisted pairs, parallel pairs, or groups of
twisted conductors or parallel pairs twisted together. The conductors or
groups of conductors may be laid parallel forming a flat, oval or round
cable. The lay of the insulated conductors are not specified. A barrier layer
and/or fillers are optional. Manufacturer shall maintain a complete
description of each assembly. May use same or mixed AWG size.
|
Covering
|
Optional,
Extruded PVC, 6 mils minimum thickness at any point, over the conductor
assembly.
|
Shield
|
Optional.
|
Extruded
PVC.
|
Construction A
|
Construction B
|
||||
Diameter of core assembly
under
|
Minimum average thickness
|
Minimum thickness at any
point
|
Minimum average thickness
|
Minimum thickness at any
point
|
|
0.350 inch or less
|
20 mils
|
17 mils
|
15 mils
|
12 mils
|
|
0.351-0.700 inch
|
30 mils
|
24 mils
|
30 mils
|
24 mils
|
|
0.701-1.000 inch
|
40 mils
|
36 mils
|
40 mils
|
36 mils
|
|
1.101-1.500 inch
|
54 mils
|
48 mils
|
54 mils
|
48 mils
|
Standard
|
Appliance
Wiring Material UL 758.
|
Marking
|
General.
|
Use
|
Construction
A: Internal wiring or external interconnection of electronic equipment in
Class 2 circuits only. Construction B: Internal wiring of electronic
equipment in Class 2 circuits only.
|