UNDERWRITERS LABORATORIES INC.          APPLIANCE WIRING MATERIAL
Subj. 758         Section 2  Page 2725        Issued:  1975-05-02
                                             Revised:  2006-11-20

Style 2725        Electronic Cable.
________________________________________________________________

Rating            60°C or 80°C, 30 V.
________________________________________________________________

Insulated         Labeled or Complies with manufacturer's AWM Procedure.
Singles           May include mixed sizes.
_________________________________________________________________

Conductor         Two, three, or four parallel, or two or more
Assembly          twisted insulated singles or groups of twisted singles
                  twisted together or groups of twisted singles may be laid
                  parallel to form flat or oval cable.  Lay not specified.
Barrier layer and/or fillers optional.  May employ a web extruded integrally with the jacket.  Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum.
_________________________________________________________________

Shield            Optional.
_________________________________________________________________

Jacket            PVC, Class 43, 9 mils minimum average, 7 mils minimum at any point, before and after ripping if a web is used.
________________________________________________________________

Standard          Appliance Wiring Material UL 758.
________________________________________________________________

Instructions      Detailed Examination.
to UL             Tensile and elongation of jacket, unaged
Representative
________________________________________________________________

UL                (4)  Detailed Examination.
Counter-Check     (4)  Tensile and elongation of jacket, unaged and aged
(4)            Heat Shock
(4)            Cold Bend
(4)   Deformation
*Program          (12) Horizontal Flame Test.
________________________________________________________________

Marking           General.
________________________________________________________________

Use               Internal wiring of electronic equipment in Class 2 systems
                  only.