APPLIANCE
WIRING MATERIAL
Subj.758
Section 2 Page 2468 Issued:1968-05-07
Revised:2013-02-22
Style 2468 Flat ribbon cable
Rating
|
80
deg C, 300 Vac, Horizontal flame. Optional - 60 or 80 deg C Oil.
|
Conductor
|
32
AWG - 16 AWG, solid or stranded.
|
Insulation
|
Extruded
PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any
point.
|
Assembly
|
Two
to one hundred and fifty conductors laid parallel and in one plane. May use
same or mixed AWG size. Minimum average and minimum at any point of
insulation thickness after ripping shall be 15 mils and 13 mils,
respectively. This forms a flat cable with a single row of conductors having
a 1/2 in. maximum width web between insulated conductors.
|
Shield
|
Optional.
|
Covering
|
Optional,
extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum
thickness.
|
Standard
|
Appliance
Wiring Material UL 758.
|
Marking
|
General.
|
Use
|
Internal
wiring.
|