APPLIANCE WIRING MATERIAL

Subj.758 Section 2 Page 2468  Issued:1968-05-07
Revised:2013-02-22
Style 2468       Flat ribbon cable

Rating
80 deg C, 300 Vac, Horizontal flame. Optional - 60 or 80 deg C Oil.
Conductor
32 AWG - 16 AWG, solid or stranded.
Insulation
Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
Assembly
Two to one hundred and fifty conductors laid parallel and in one plane. May use same or mixed AWG size. Minimum average and minimum at any point of insulation thickness after ripping shall be 15 mils and 13 mils, respectively. This forms a flat cable with a single row of conductors having a 1/2 in. maximum width web between insulated conductors.
Shield
Optional.
Covering
Optional, extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.