APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3271 Issued:1972-08-02
Revised:2011-10-04
Style 3271 Single conductor with extruded sulation.
Rating
|
125 deg C, 600 Vac, 750 Vdc, Horizontal
flame.
|
||
Conductor
|
30 AWG - 1000 kcmil solid, stranded, or
braided, tinned, bare or silver-plated
copper or solid or stranded coated high strength copper - minimum 90 percent conductivity. |
||
Insulation
|
Extruded XLPE.
|
||
Conductor size
|
Minimum average thickness
|
Minimum thickness at any point
|
|
30-9 AWG
|
30
mils
|
27 mils
|
|
8-2 AWG
|
45
mils
|
40 mils
|
|
1-4/0 AWG
|
55
mils
|
50 mils
|
|
213-500 kcmil
|
65
mils
|
58 mils
|
|
501-1000 kcmil
|
80
mils
|
72 mils
|
|
1001-2000 kcmil
|
95
mils
|
86 mils
|
|
Standard
|
Appliance Wiring Material UL 758.
|
||
Marking
|
General.
|
||
Use
|
For use as Motor Leads or Internal Wiring
of appliances. Tags may indicate the following: 2500 volt peak - For
Electronic Use Only.
|